日韩成人免费视频一三区|91久久精品一区二区三区全区|91久久精一区二区三区大全|silk中文字幕在线一区二区

QuEChERS pre-processing all-in-one machine

Model:JX-QE-CL

Brand:Shanghai Jingxin

Specifications :One Set

Introduction:Product introduction: Shanghai Jingxin?'s JX-QE-CL?QuEChERS pre-processing all-in-one machine (patented product, counterfeiting must be punished! ZL2017305264903) is a special, fast, efficient, multi-test tube consistent system.

Shanghai Jingxin?'s JX-QE-CL?QuEChERS pre-processing all-in-one machine (patented product, counterfeiting must be punished! ZL2017305264903) is a special, fast, efficient, multi-test tube consistent system. It can extract and purify the original DNA, RNA and protein from any source (including soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, paleontological specimens, etc.).

Technical parameter:

Main parameters

Parameter range

Application areas:

tissue homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, sample mixing, shaking

Sample processing:

It can handle 64 samples at the same time in 15 seconds, including liquid nitrogen refrigeration adapters that can be used for 12 and 24 positions

Compatible sample volume:

64*(0.2-0.5ML)/64*2ML/12*(5-15)ML/4*25ML/2*50ML, various specifications of grinding tubes can be customized

Touch screen display:

convenient and intuitive operation

Data storage:

Ten groups of experimental data can be stored. According to different experimental samples, animal heart, spleen, lung, kidney, bone, skin, and hair modes are set.

Mode cycle:

According to the set experimental parameters, it can continuously circulate among several set parameters to further reduce the interference of human factors

Feeding size:

No requirement, adjust according to adapter

Refrigeration function:

Yes, adjustable from -30 degrees to 37 degrees

Temperature control accuracy:

+0.5 degrees

Open cover operation protection:

electromagnetic lock

Discharge size:

~5μm

The number of grinding platforms (the number of grinding tanks that can be accepted)

>2

Fastening device with automatic centering

support

Homogenization speed and time:

0—70 HZ/sec, working time: 0 seconds to 9999 minutes, users can set by themselves;

Diameter of grinding ball:

0.1-30mm

Grinding ball material:

alloy steel, chromium steel, zirconia, tungsten carbide, quartz sand;

Acceleration:

reach a greater speed in 2 seconds

Deceleration:

reach a lower speed in 2 seconds

Noise:

<55db

Grinding method:

wet grinding, dry grinding and low temperature grinding are all available

Refrigeration:

It has the ability to upgrade to ultra-low temperature liquid nitrogen refrigeration or air refrigerator refrigeration

Adapter material:

PTFE or alloy steel

Full protection:

Fastening device with automatic center positioning, safety lock during work, full protection

Grinding kit material:

hard rigid, PTFE (Teflon) zirconia

Dimensions:

630mm*300mm*480mm

Weight:

58KG


◆ Basic configuration:

1. A set of JX-QE-CL system machines.

2. Freeze grinding module 1.5-2.0ml*24 set, 7-10ml*8 set, 25ml*2 set.

3. PTFE tube 15ml, a set of 15ml. A set of 25ml stainless steel grinding tank, a set of 25ml PTFE

4. One bottle of ceramic beads for grinding and one bottle of stainless steel beads.

Typical application:

Typical application one, QUECHERS method of rapid sample pretreatment for pesticide residue inspection:

1. JX-QE16 automatic QuEChERS pre-processing all-in-one machine homogenizes 10g of samples and adds 10ml of acetonitrile;

2. JX-QE16 automatic QuEChERS pre-processing all-in-one machine oscillates for 1 min, add 1g of sodium chloride and 4g of magnesium sulfate;

3. The JX-QE16 automatic QuEChERS pre-processing integrated machine oscillates for 1 min and centrifuges at 5000 rpm for 10 min to aliquot 1 ml of the acetonitrile layer and add 250 mg of magnesium sulfate 150 mg PSA powder;

4. The JX-QE16 automatic QuEChERS pre-processing integrated machine oscillates for 1 min, and the supernatant is centrifuged and analyzed by GCMS.

Typical application 2: LC/MS method for extracting OTC drugs in water and sludge cake:

1), sample preparation

Put 3.76mL water, 20uL cetirizine, diphenhydramine and diclofenac, and 140μL acetaminophen into a 50ml centrifuge tube. For the sludge sample experiment, weigh the 2.5k freeze-dried sludge and add the same amount of water and medicine as mentioned above. Add 10mL acetonitrile and add it to the EN extraction tube. After JX-QE16 works with a 50ML adapter for 1 minute, it is centrifuged at 4000rpm for 5 minutes.

To

Dispersive solid-phase extraction: Take the supernatant (about 7mL) and place it in the d-SPE dispersive solid-phase extraction package. Use the 15ML adapter for JX-QE16 for 1 minute, and then centrifuge at 4000 rpm for 5 minutes. Then the extracted supernatant was transferred to a clean 15mL centrifuge tube and evaporated to dryness with nitrogen. Use 1.875 mL of 50:50 acetonitrile and water to make a sample solution.

Inquiry message
*Name:

*Company/City:
*Phone:
*Contact:
*City:
*Code: